Artixio

ANVISA Generic Drug Registration Requirements in Brazil

ANVISA generic drug registration requirements in Brazil

ANVISA generic drug registration is how a company proves that a generic medicine can safely replace its Brazilian reference medicine. You cannot manufacture, import, distribute or market a medicine in Brazil before the National Health Surveillance Agency (ANVISA) regularizes it. The dossier combines regulatory documents, pharmaceutical equivalence, bioequivalence or a bio-waiver and Good Manufacturing Practices (GMP) compliance.

This article covers the requirements, documents, process and checks for foreign manufacturers.

What Is Generic Drug Registration in Brazil?

Generic drug registration in Brazil is ANVISA’s approval of a medicine intended to be interchangeable with a reference medicine. A generic is similar to a reference or innovative product and usually reaches the market after patent or exclusivity rights end. The reference medicine is the benchmark for the comparison. It is a new or innovative medicine already regularized by ANVISA and sold in Brazil.

A generic uses the Brazilian Common Denomination (DCB), or the international nonproprietary name if no DCB exists, instead of a brand name. Generic medicine registration in Brazil applies only to eligible products.

ANVISA Regulations for Generic Drug Registration

ANVISA generic drug requirements are covered by two main resolutions. Additional rules cover bioequivalence studies, manufacturing quality, and active pharmaceutical ingredient (API) quality.

Regulation What to use it for
RDC 753/2022
The minimum documents a generic dossier must contain, and the medicine classes that cannot be registered as generics.
RDC 948/2024
General requirements: holder authorizations, GMP certificates, filing, and registration validity. It took effect on 1 January 2025 and revoked several RDC 753 provisions, including administrative documents. RDC 991/2025 later amended it.
RDC 957/2024
For checking that the reference medicine meets the criteria and is on the Reference Medicines List.
RDC 742/2022 and RDC 749/2022
RDC 742 sets how bioequivalence studies are conducted. RDC 749 covers bioequivalence waivers.
RDC 359/2020
The API dossier (DIFA) and its adequacy letter (CADIFA).

Requirements vary with dosage form, active ingredient, route, and petition category.

Eligibility Requirements for Generic Medicines

Before dossier work begins, the manufacturer should confirm eligibility. The reference medicine must be registered and marketed in Brazil, and the generic must match it on dosage form, route, and amount of the same active substance.

Under RDC 753/2022, the manufacturer must file one request per dosage form, and all strengths go into one process if their reference medicines differ. The manufacturer must support the request with pharmaceutical equivalence, dissolution, and bioequivalence or bio-waiver evidence from the same batch, unless it justifies otherwise. A product that qualifies as a generic cannot be filed as a new medicine instead. Biological products, herbal medicines, dynamized medicines, radiopharmaceuticals and medicinal gases cannot be registered as generics.

ANVISA can reclassify a product, and that may change the fee and move the petition to another queue. Eligibility therefore shapes the manufacturer’s regulatory strategy, reference selection, studies, documents and petition category.

One practical issue manufacturers face is starting detailed dossier work before the product, reference medicine, and registration category are aligned. Settling that early can prevent avoidable rework and repeated studies.

Documents Required for ANVISA Generic Drug Registration

The documents required for generic drug registration in Brazil fall into five groups.

Administrative documentation: The petition must cover the request, the company and its operating authorization, the product, formula, manufacturers, and presentations. The manufacturer must also include proof of fee payment or exemption, its ANVISA interaction history, and the Product Technical Report, a summary of quality, safety, and efficacy with the applicant’s critical assessment.

Pharmaceutical quality documentation: The manufacturer must submit formulation development, composition, a production dossier for one batch, specifications, validated analytical methods, quality-control reports, and packaging details. Stability data must come from three batches, with photostability results or a justification. The manufacturer must also assess nitrosamine risk.

Active Pharmaceutical Ingredient (API) documentation: The DIFA is the API’s quality dossier. The CADIFA is ANVISA’s letter confirming that the DIFA meets RDC 359/2020. Any registration that adds or replaces a DIFA needs a CADIFA request. The manufacturer must provide API manufacturer details, a letter from the DIFA holder or a copy of the CADIFA with the access declaration, a GMP declaration, and the API GMP certification request number. ANVISA grants registration only with a valid API GMP certificate and CADIFA.

Generic-specific evidence: It must include the pharmaceutical equivalence certificate, the dissolution profile certificate, and bioequivalence or bio-waiver documentation. It must also include a dissolution method development report, unless both products are made at the same site with identical formulation, process, and equipment.

Labeling and product information. It must include package insert text and layouts for the primary and secondary packaging of each presentation. New petitions must meet RDC 768/2022. For generics:

  • The pack must carry the generic logo, a stylized “G” with “Medicamento Genérico.”
  • The front face must show the DCB name, each API concentration, route, dosage form, use restriction, company name or logo, and total quantity.
  • Ingredient order and concentrations must match the reference medicine.
  • The label must state “CONTÉM” for sugar, lactose, colorants, gluten, sweeteners, or alcohol. It must not claim their absence, and it must not show distributor or pharmacy names or logos.

The 28 June 2026 deadline for adapting registered generics has passed, so new filings should meet the current text from the start.

The exact dossier checklist depends on the product, dosage form, active ingredient, and applicable ANVISA petition category.

Pharmaceutical Equivalence and Bioequivalence Requirements

Pharmaceutical equivalence and bioequivalence studies are conducted to demonstrate that a generic medicine meets the required standards compared with the reference medicine.

Pharmaceutical equivalence tests show that the two products are pharmaceutical equivalents. The dissolution profile compares drug release under applicable conditions. Bioequivalence shows equivalent bioavailability when both products are studied in the same design. A bio-waiver can replace the bioequivalence study when ANVISA’s criteria are met, but not every product qualifies.

ANVISA bioequivalence requirements depend on the drug, dosage form, route, and product conditions. Topical corticosteroids, for example, have required pharmacodynamic studies. ANVISA also lists the fasting or fed condition and the analyte for each drug in conventional-release forms.

The manufacturer must buy the comparator in Brazil. It must run the bioequivalence or bio-waiver tests on the same batch as the equivalence study, unless it justifies otherwise. The reports go into the dossier where applicable.

ANVISA Generic Drug Registration Process

The ANVISA drug registration process for a generic medicine has six steps, from the first assessment to ANVISA’s decision.

Step 1: Regulatory Assessment: Confirm eligibility, reference medicine, route, petition category, required studies, and bio-waiver options. Before filing, the manufacturer can request ANVISA’s guidance, though ANVISA can still reach a different decision.

Step 2: Dossier Preparation: Compile only the documents that apply. The manufacturer can use the Common Technical Document (CTD), a standard dossier layout.

Step 3: Application Submission: File under RDC 947/2024 and pay the fee or show an exemption. Confirm the current submission system first.

Step 4: Regulatory Review: ANVISA evaluates the regulatory information, quality data, studies and supporting evidence.

Step 5: Respond to Regulatory Questions: Coordinate regulatory, quality, manufacturing, and technical teams. Answer within the deadline stated in the query.

Step 6: Registration Decision: ANVISA publishes decisions in the Official Gazette. Outcomes include approval or rejection. Submission does not guarantee approval.

Requirements for Foreign Pharmaceutical Manufacturers

ANVISA registration for foreign pharmaceutical companies depends on the registration holder’s structure, which differs by case. The foreign manufacturer and the Brazilian registration holder are not always the same entity. The holder must have an importer operating authorization where manufacturing is abroad, a sanitary license and a special authorization if controlled substances are involved. The manufacturing site must have a valid ANVISA GMP certificate or a pending certification request.

For imported products, the manufacturer must provide the registration certificate or equivalent from the country of origin, plus the product’s regulatory status in other countries. Official foreign-language documents need a sworn translation, except those in English or Spanish. The manufacturer should also align with its API manufacturer on Active Pharmaceutical Ingredient Dossier (DIFA), Letter of Adequacy (CADIFA), and API GMP status.

Before starting Brazil pharmaceutical registration, the manufacturer should assess its local arrangements, manufacturing compliance, API documents and holder structure.

Post-Registration Compliance Requirements

Approval starts a set of lifecycle duties, and ANVISA post-registration requirements cover several areas. Registration is valid for 10 years. To keep it in force, the manufacturer must submit the required revalidation documents, including a formal statement of interest when manufacture has been discontinued.

Post-approval changes fall into two groups, depending on their potential impact on quality, safety, and efficacy. The manufacturer can implement immediate-implementation changes straight away, recording them in the Product Change History or filing an individual petition. Changes that need prior approval must wait for ANVISA’s favorable decision, and the manufacturer then has 180 days to implement. The manufacturer must also file the Product Change History every year, in the month of the registration anniversary, even if nothing changed.

The manufacturer must also monitor adverse events and other medicine problems under ANVISA’s pharmacovigilance rules, and report any discontinuation or reactivation of manufacture or import. If an operating authorization lapses, it must stop the related activity. ANVISA can request more evidence or audit even after approval. Brazil pharmaceutical regulatory compliance continues for the whole product lifecycle.

Maintaining compliance after registration also requires pharmaceutical companies to stay informed about changes in ANVISA regulations and guidelines. Artixio’s Qurious RI helps companies track regulatory updates from health authorities worldwide and receive personalized alerts on relevant changes, supporting ongoing regulatory compliance.

Conclusion

ANVISA generic drug registration works best when strategy comes before the dossier. It needs a clear regulatory strategy, complete documents, suitable equivalence and bioequivalence evidence, API and manufacturing compliance and steady handling of ANVISA’s review. Assess the product and requirements before submission.

Pharmaceutical companies preparing to register generic medicines in Brazil can benefit from regulatory support with eligibility assessment, dossier review, bioequivalence planning, ANVISA submission management and responses to regulatory queries. Reach out to info@artixio.com for guidance tailored to your product. Explore Artixio’s Brazil regulatory affairs services to learn more about our services, or contact us at info@artixio.com.

FAQs

Q1. What is required to register a generic drug in Brazil?

A medicine cannot be manufactured, imported, distributed, or marketed in Brazil until ANVISA regularizes it. The manufacturer needs an eligible product with a reference medicine registered and marketed in Brazil. The dossier must include pharmaceutical equivalence, dissolution, and bioequivalence or bio-waiver evidence, API documentation, and proof of GMP compliance.

Q2. Does a generic drug need a bioequivalence study in Brazil?

A generic must either show bioequivalence to the reference medicine or qualify for a bio-waiver under ANVISA’s criteria. Not every product qualifies for a waiver. The requirements depend on the drug, dosage form, and route. The comparator must be bought in Brazil, and the tests must use the same batch as the equivalence study unless the manufacturer justifies otherwise.

Q3. Can a foreign manufacturer register a generic drug in Brazil?

Yes, but the foreign manufacturer and the Brazilian registration holder are not always the same entity. The holder must have an importer operating authorization where manufacturing is abroad. The manufacturing site needs a valid ANVISA GMP certificate or a pending certification request. Official foreign-language documents need a sworn translation, except those in English or Spanish.

Q4. How long is a generic drug registration valid in Brazil?

Registration is valid for 10 years. To keep it in force, the manufacturer must submit the required revalidation documents, including a formal statement of interest when manufacture has been discontinued. Post-approval changes also need handling: lower-risk changes can be implemented immediately and moderate-risk and high-risk changes need ANVISA’s authorization first.

Get in touch

×